Field Evaluation Of Attic–Indoor Temperature Dynamics Beneath A Lightweight Metal Roof In A Hot-Humid Tropical Climate, Owerri, Nigeria

Authors

  • Obinna E. Ukanwa Department of Architecture, Imo State University, Owerri, Nigeria Author
  • Kelechi E. Ezeji Department of Architecture, Chukwuemeka Odumegwu Ojukwu University, Uli Campus, Uli, Anambra State, Nigeria Author
  • Ndidi U. Okolo Department of Architecture, Chukwuemeka Odumegwu Ojukwu University, Uli Campus, Uli, Anambra State, Nigeria Author

Keywords:

Attic-indoor dynamics, Field monitoring, Hot-humid climate, Lightweight roof, Thermal attenuation

Abstract

Lightweight metal roofs are widely used in hot-humid residential environments, yet long-term field evidence on the relationship between attic and occupied-space air temperatures beneath such roof configurations remains limited. This study evaluated the diurnal and seasonal attic–indoor temperature dynamics of a residential building in Owerri, Nigeria, comprising a black stone-coated metal roof, an attic with no purpose-provided ventilation, and a plaster-of-Paris ceiling. Attic and occupied-space air temperatures were synchronously monitored from 2 October 2024 to 22 June 2025 at six-hour intervals, yielding 1,052 paired observations. Descriptive statistics, temperature-amplitude analysis, Pearson correlation and ordinary least-squares regression were used to characterise the relationship between the two monitored environments, with Newey–West heteroskedasticity- and autocorrelation-consistent standard errors applied to regression inference. Mean attic air temperature was 31.15 °C compared with 30.57 °C in the occupied space, while temperature amplitudes were 7.40 °C and 5.85 °C, respectively, corresponding to an attic-to-indoor temperature-amplitude ratio of 0.79. Mean attic–indoor temperature difference decreased from 0.66 °C during the dry-season period to 0.40 °C during the wet-season onset. Attic and occupied-space temperatures were strongly positively correlated (r = 0.956, p < 0.001), and the regression model showed a high degree of shared linear variation (R² = 0.913). These findings provide field-based observational evidence of strong but temporally variable thermal coupling between the attic and occupied space for the investigated roof–attic–ceiling configuration. They further indicate the relevance of considering roof solar heat gain, attic ventilation and ceiling thermal resistance within an integrated building–environment approach to passive thermal design. The findings are configuration-specific and do not establish attic temperature as an independent cause of occupied-space thermal conditions.

Downloads

Published

30-09-2026

Issue

Section

Architecture

How to Cite

Field Evaluation Of Attic–Indoor Temperature Dynamics Beneath A Lightweight Metal Roof In A Hot-Humid Tropical Climate, Owerri, Nigeria. (2026). Coou African Journal of Environmental Research, 7(2), 197-224. http://ajer.org.ng/index.php/journal/article/view/329

Similar Articles

1-10 of 61

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

1 2 > >>